72 Programming SATEL
For the pulse, A
DEMCO
E
XPRESS
, C
ONTACT
ID
(
SELECTED
) or SIA
(
SELECTED
) formats, you must
define which events will be sent with the given identifier (see: section I
DENTIFIERS
ASSIGNMENT
).
For the C
ONTACT
ID
(
FULL
) or SIA
(
FULL
) formats, each object has its own identifier.
Therefore, the identifiers of non-existing objects need not to be programmed. In the
system event identifier field, you should re-enter the identifier of the object which is
responsible for the system (for example, the object, where the control panel is
installed).
SIA / TELIM prefix
2 characters which will precede each of the identifiers in case of the SIA and TELIM formats.
Thus an identifier consisting of 6 characters can be obtained. 2 hexadecimal characters
(digits or letters from A to F) can be programmed. Entering 00 means that the prefix will not
be added. Using the digit 0 in the prefix is not recommended.
Events assignment
If the events are to be sent to both stations (S
TATION
1
AND
2
is selected), you can define
which event types will be reported to the given station.
It is not possible to assign events for the C
ONTACT
ID
(
FULL
) and SIA
(
FULL
) formats.
9.1.4 SIA-IP
If events are to be sent in the SIA-IP format, you must program additional parameters for
each monitoring station.
Send MAC address [MAC] – if this option is enabled, the MAC address of ETHM-1 or GSM
module will be sent with event code.
Send timestamp [Timestamp] – if this option is enabled, the date and time will be sent with
event code.
Encrypt data [Coded] – if this option is enabled, the data to be sent will be encrypted, and
the date and time will be sent with event code.
SIA-IP key – the key to encrypt data to be sent to the monitoring station using the SIA-IP
format (a string of up to 16 alphanumeric characters).
Supervision interval [SIA-IP test] – an additional transmission can be sent at specified
intervals to check communication with the monitoring station. You can program a number
of days, hours, minutes and seconds between the transmissions.
9.1.5 Identifiers assignment
Define the identifier with which events relating to individual partitions, zones, keypads and
expansion modules will be sent. If no identifier is assigned to the given element of the
system, it will be impossible to define codes for events relating to it.
9.1.6 Event codes
For the pulse and Ademco Express formats, it is necessary to program codes which will be
reported to the monitoring station if the defined events occur. The reported events are those
for which a code different from "00" has been programmed. 2 hexadecimal characters (digits
or letters from A to F) are to be programmed.
In case of the C
ONTACT
ID
(
SELECTED
) and SIA
(
SELECTED
)
formats, indicate the events
which are to be reported, entering for them any code different from "00" (a code
consistent with the format specification will be sent, not the entered one). The events
for which the "00" code has been programmed will not be reported.