Satel INTEGRA Plus Specifications Page 34

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 33
32 Programming SATEL
address is given in the SMS message (the computer address programmed in the GSM
module will be ignored).
6. The D
LOAD
X program will inform you about establishing connection by means of
a suitable message.
3. System structure
The system can be subdivided into objects (subsystems). Partitions are assigned to each
object and zones are assigned to partitions.
3.1 Objects
The objects are treated as separate alarm systems. By default, one object is created in the
control panel. New object can be created:
using the keypad, in the service mode, by means of the N
EW OBJECT
function
(S
TRUCTURE
S
YSTEM
O
BJECTS
N
EW OBJECT
) – having started the function, select
the object to be created (after an object is created, the LCD keypad will automatically
display the functions to allow you to assign partitions to objects and to name the objects);
using the D
LOAD
X program, in the "Structure" window, "System" tab, after clicking on the
system name – a new object will be created after you click on the "Add" button.
Fig. 2. Presentation of the system structure in the D
LOAD
X program.
3.2 Partitions
The partition is a separated area within the premises protected by the security alarm system.
The subdivision into partitions enables arming/disarming the system only in part of the
protected area, as well as limiting access to some portion of the premises to selected users.
3.2.1 Creating partitions
A new partition can be created and, at the same time, assigned to an object:
using the keypad, in the service mode, by means of the P
ARTITIONS
function (S
TRUCTURE
S
YSTEM
O
BJECTS
E
DIT OBJECT
[select object from list] P
ARTITIONS
) – see:
S
ELECTION FROM THE MULTIPLE
-
CHOICE LIST
p. 21;
Page view 33