Satel INTEGRA Plus Specifications Page 7

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 6
SATEL INTEGRA Plus 5
2.1.2 Starting the service mode "from pins"
When entering the service mode in the normal way is not possible (the control panel does not
support LCD keypads, does not accept the service code, etc.), you can use the emergency
procedure, so-called, starting "from pins."
1. Turn off the control panel power supply (first disconnect the AC power, and then the
battery).
2. Put a jumper on the RESET pins located on the control panel mainboard.
3. Turn on the control panel power supply (first connect the battery and then the AC power).
The DIALER LED will start blinking.
4. Wait a few seconds until the DIALER LED goes out and remove the jumper from the pins.
The control panel will enter the service mode. The service mode menu will be displayed
on the LCD keypad with the lowest address.
The service mode will not start if:
the computer with running D
LOAD
X program is connected to the RS-232 port;
the D
ISABLE
S
ERVICE
M
ODE
option is enabled – in such a case a prompt will appear
on the display, whether you want to delete all the control panel data. Pressing the
key number 1 will restore the factory settings and then will start the service mode.
The service mode can be started "from pins" even if the installer does not have access
(the administrator has disabled the P
ERMANENT SERVICE ACCESS
and has not
programmed the service access time). If this is the case, the installer can get access
to the M
ASTERS
function by entering the service code, confirmed by pressing the
key,
within about 20 seconds after ending the service mode started "from pins".
2.1.3 Hiding the service mode
The installer can hide the service mode using the H
IDE
SM
NOW
function (SM
SETTINGS
H
IDE
SM
NOW
). The control panel will remain in the service mode, but the service mode menu will
not be displayed. This function can be useful, if e.g. the installer has to leave the keypad, but
does not want unauthorized persons to have access in the meantime to the service menu. To
get access to the service mode menu, you must proceed in the same way as when entering
the service mode.
The service mode can be hidden automatically after a specified period of time has elapsed
since the last operation was performed on the keypad (see description of the H
IDE SERVICE
MODE AFTER
parameter p. 61).
2.1.4 Exiting the service mode
To exit the service mode you can use the S
ERVICE END
function.
After exiting the service mode, the control panel verifies whether the data in RAM memory
have changed in relation to the data stored in non-volatile FLASH memory. When the data in
RAM have been changed, a prompt will be displayed asking whether the new settings are to
be saved to FLASH memory. Pressing the key with number 1 will save a copy of the settings
to FLASH memory. By saving a copy of the settings to the FLASH memory, the control panel
will be able to restore them from a backup copy if an error is detected in the data stored in
the RAM memory.
2.1.5 Service mode menu
Service end
SM settings
Service code
INTEGRA ident.
DloadX ident.
Page view 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 81 82

Comments to this Manuals

No comments