SATEL INTEGRA Plus 65
Alarms – you can define which alarms will be triggered from the keypad:
fire – pressing the
key for approx. 3 seconds.
panic – pressing the key for approx. 3 seconds.
auxiliary [medical] – pressing the key for approx. 3 seconds.
3 wrong codes – entering invalid access codes three times.
Silent PANIC alarm [Silent panic] – with this option enabled, pressing the key for approx.
3 seconds will trigger the silent panic alarm.
Sign. entry delay [Entry time s.] – with this option enabled, the keypad will audibly signal the
entry delay countdown.
Sign. exit delay [Exit time sig.] – with this option enabled, the keypad will audibly signal the
exit delay countdown.
Sign. alarms [Alarm signal.] – with this option enabled, the keypad will signal the alarms
audibly.
Key sounds [Key sounds] – with this option enabled, pressing the keypad keys is confirmed
by beeps.
Sign. trbl. in part. arm [Trbl.in p.arm.] – with this option enabled, the keypad signals troubles
by means of the
LED, if some of the operated partitions are armed (the troubles are
not signaled if all partitions are armed).
Sign. new trouble [New trbl.sign.] – with this option enabled, the keypad can audibly signal
the occurrence of a new trouble (if the T
ROUBLE MEMORY UNTIL REVIEW
option is enabled).
New trouble signaling is cleared after the troubles have been reviewed by the user.
Show code entering [Show code ent.] – with this option enabled, entering the code is
presented on the keypad display by asterisks.
Show keypad name [Name (2nd row)] – with this option enabled, the keypad name is
presented in the lower line of the display.
Exit delay clearing enable [Fin.exit time] – with this option enabled, the exit delay time in
partitions with the E
XIT DELAY CLEARING
option enabled can be shortened after pressing in
turn the 9
keys.
Show viol. zones [Zone violation] – with this option enabled, violating the CHIME signal
triggering zone result additionally in the zone name being displayed.
Auto-Arm delay countdown [Auto-arm delay] – with this option enabled, the auto-arm delay
countdown in partition is signaled acoustically.
Signal on wrong card [Unkn.card sig.] – option available for the INT-KLCDR and INT-KLFR
keypads. If enabled, reading in an unknown card will be signaled by two long beeps.
Event after 3 readings [Ev.3 unk.cards] – option available for the INT-KLCDR and
INT-KLFR keypads. If enabled, reading in an unknown card three times will save the
event.
Alarm after 3 readings [Al.3 unk.cards] – the option is available, if the E
VENT AFTER
3
READINGS
option is enabled. When enabled, reading in an unknown card three times will
trigger an alarm.
Displ. mode switching [Dspl.mode chg.] – with the option enabled, you can toggle the
display between the standby mode and the partition status display mode by using the 9
key.
Show disarm messages [Show disarming] – if this option is enabled, the keypad will inform
about disarming with a displayed message at all times. If the option is disabled – only in
case of disarming from the given keypad.
Show arm messages [Show arm] – if this option is enabled, the keypad will inform about
arming with a displayed message (irrespective of how the system was armed).