Satel INTEGRA Plus Specifications Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
SATEL INTEGRA Plus 49
The pulse duration is approx. 0.3 seconds.
24. MONO
S
WITCH
– controlled by users, zones or timers. Using a code, zone violation or
turning timer on will activate the output for a preprogrammed time.
25. BI
S
WITCH
– controlled by users, zones or timers. Depending on the current status, using
a code or violating a zone will activate/deactivate the output. Turning the timer ON
activates the output, and turning the timer OFF deactivates the output.
If the 24. MONO
S
WITCH
or 25. BI
S
WITCH
type output is to be controlled from the
keypad, it must be assigned to a group of outputs (see: section O
UTPUT GROUPS
p. 54).
26. T
IMER
– the output controlled by timers.
27. T
ROUBLE STATUS
– indicates the troubles.
28. AC
LOSS
(
MAINBOARD
)
IMMEDIATE
– indicates the loss of AC power to the control panel
mainboard.
29. AC
LOSS
(
TECHNICAL ZONE
) – indicates the violations of 59. T
ECHNICAL
-AC
LOSS
type
zones.
30. AC
LOSS
(
EXPANSION MODULE
) – indicates the loss of AC power to the modules with power
supply.
31. B
ATTERY TROUBLE
(
MAINBOARD
) – indicates the low battery of the control panel mainboard.
32. B
ATTERY TROUBLE
(
TECHNICAL ZONE
) – indicates the violations of 60. T
ECHNICAL
-B
ATTERY
LOW
type zones.
33. B
ATTERY TROUBLE
(
EXPANSION MODULE
) – indicates the low battery of the modules with
power supply.
34. D
ETECTOR TROUBLE
– indicates the zone troubles.
35. T
ELEPHONE LINE IN USE STATUS
– indicates that the telephone communication is in use.
36. G
ROUND
S
TART
– generates a control pulse necessary for work with some types of
telephone exchange.
37. R
EPORTING ACKNOWLEDGEMENT
– indicates the acknowledgement of reporting.
38. S
ERVICE MODE STATUS
– indicates that the service mode is entered.
39. T
EST VIBRATION DETECTORS
– intended for testing the vibration detectors in one partition
(see: 10. 24
H
V
IBRATION
zone type). The output cut-off time defines the duration of testing
the vibration detectors in the selected partition.
40. C
ASH MACHINE BYPASS STATUS
– indicates bypassing the 11. 24
H
C
ASH MACHINE
type
zones in partitions with cash dispenser.
41. P
OWER SUPPLY
– intended for supplying external devices.
42. P
OWER SUPPLY ON ARMED
– dedicated to powering the detectors which should not be
active when the system is disarmed. Gets active when the arming procedure is started
(active during the exit delay countdown).
43. R
ESETABLE POWER SUPPLY
– the power supply output with optional reset by the user. The
programmed cut-off time is the time during which the output will be turned off.
44. F
IRE DETECTORS POWER SUPPLY
– intended for supplying the fire detectors with automatic
alarm verification. Violating the fire zone will turn the power off (for the time programmed
as the output cut-off time) and if another violation occurs after the power is turned on
again, the fire alarm will be triggered. The output can be reset by the user.
45. P
ARTITION BLOCK STATUS
– indicates a temporary blocking of the partition armed status. If
the output cut-off time is different from 0, the output will signal that the partition blocking is
ending (the output will turn on for a programmed time before the blocking ends).
46. O
UTPUTS LOGICAL
AND – active when all the control outputs with normal polarity are
active and all the control outputs with reversed polarity are inactive (because of the