4 Programming SATEL
1. General
This manual applies to the control panels of the INTEGRA Plus series:
INTEGRA 64 Plus
INTEGRA 128 Plus
INTEGRA 256 Plus
2. Programming options
The control panel may be programmed:
locally
– LCD keypad;
– computer with the D
LOAD
X program installed, connected to the control panel RS-232 or
USB port;
remotely
– computer with the D
LOAD
X program installed, communicating via the telephone network
(through modem or GPRS) or via the Ethernet network;
virtual keypad available in the internet browser, mobile phone or smartphone.
Programming the control panel is possible when:
– the P
ERMANENT SERVICE ACCESS
option is enabled (the option is enabled by default – the
control panel can be programmed by any method);
– the P
ERMANENT
D
LOAD
X
ACCESS
option is enabled (the option is enabled by default – the
control panel can only be programmed by means of the D
LOAD
X
program);
the installer has been granted a temporary access to the control panel using the
S
ERVICE ACCESS
function (the control panel can be programmed by any method).
The standards require that the administrators (masters) limit the installer access after
installation is finished.
2.1 Keypad
Programming the control panel with keypad (real or virtual) should be carried out using the
service functions, available in the service mode menu. Some features may not be available in
the virtual keypads.
2.1.1 Starting the service mode
1. Enter the service code (by default 12345) and press the key.
2. Using the or key, select the item S
ERVICE MODE
from the list and press the or
key.
You can also start the service mode using the key shortcut:
[service code] 9
The service mode is indicated in the keypads by lighting of the LED. It can also be
signaled by beeps if the appropriate option is enabled.
In the service mode, only alarms from the 24
H
V
IBRATION
, 24
H
C
ASH MACHINE
, P
ANIC
-
AUDIBLE
and P
ANIC
-
SILENT
type zones are possible.