56 Programming SATEL
5. System options
Most of the options and parameters described in this section can be programmed:
using the keypad, in the service mode, by means of the functions available in the O
PTIONS
submenu;
using the D
LOAD
X program, in the "Options" window.
Shown in square brackets are the names used in keypads.
5.1 Telephone options
Reporting - TELEPHONE [Mon.TELEPHONE] – with this option enabled, the control panel
can send event codes by means of the telephone line.
Reporting - GPRS [Mon.GPRS] – with this option enabled, the control panel can send event
codes using GPRS technology (the SATEL GSM module must be connected to the control
panel). This does not apply to the TELIM format.
Reporting - ETHM [Mon.ETHM-1] – with this option enabled, the control panel will be able to
send event codes to the monitoring station via the Ethernet network (the SATEL ETHM-1
module must be connected to the control panel). This does not apply to the TELIM format.
Telephone messaging [Messaging] – if this option is enabled, the control panel can send
notifications via the telephone network of the occurrence of specific events using voice or
text messages defined by the installer.
SMS messaging – if this option is enabled, the control panel can send notifications of the
occurrence of specific events using SMS messages, the content of which is consistent with
event description in the event log (the SATEL GSM module must be connected to the
control panel).
Answering - modem [Modem answer.] – with this option enabled, external initiation of the
communication between modem and control panel is possible.
Answering - audio [Voice answer.] – with this option enabled, the control panel will carry out
the function of call answering.
The A
NSWERING
-
AUDIO
option must be enabled, if the users are to operate the alarm
system using the interactive voice menu offered by the INT-VG module.
Remote control – with this option enabled, the control panel allows the users having
a telephone code to operate the R
EMOTE SWITCH
outputs by using a phone. The option is
available if the A
NSWERING
AUDIO
is enabled.
External modem [External modem] – with this option enabled, the control panel will support
an external modem connected to the control panel RS-232 port.
Modem ISDN/GSM/ETHM [ISDN/GSM modem] – enable this option if the GSM, ISDN or
ETHM-1 module is connected as the external modem. The option is available if the
E
XTERNAL MODEM
option has been enabled.
Answering - ETHM/GSM [Ext.mod.answ.] – if this option is enabled, it is possible to initiate
communication with the control panel from the outside, by means of the ETHM-1 module,
GSM or ISDN modem. The option is available, if the E
XTERNAL MODEM
and
M
ODEM
ISDN/GSM/ETHM options are enabled. The option is not available when the A
NSWERING
-
MODEM
option is enabled, which also enables communication with the control panel to be
initiated from the outside, by means of the ETHM-1 module, GSM or ISDN modem.
Tone dialing – with this option enabled, the control panel will tone dial the telephone
numbers (pulse dial, if this option is disabled).
Ground Start – with this option enabled, the control panel will use the Ground Start method
to obtain signal on the telephone line (by grounding temporarily the telephone line wires).
Enable this option, if required by your phone service provider.