Page view 62
SATEL INTEGRA Plus 61
Times 5.5
Globa s, for which the
programmed E
NTRY DELAY
is equal to 0.
ime – time of signaling alarm in keypads, proximity card arm/disarm devices,
programmed the value 0
5.
l entry delay – parameter taken into account in the delayed zone
Global alarm t
proximity card readers and DALLAS chip readers.
No armed indication after – time counted from the moment of partition arming, during which
information about armed status is displayed on the keypads.
Default partition block time – the time period during which the W
ITH TEMPORARY BLOCK
type
partitions with enabled D option w
EFAULT BLOCK TIME
ill be blocked.
AC loss report delay – time during which the control panel must not receive AC power so
that information of it can be saved to the event log. Having
means that the information of AC power loss will not be saved to the event log.
uring which abnormal vTelephone line loss report delay – time d oltage must be on the
telephone line for the control panel to report the telephone line trouble. A delay in reporting
the trouble prevents sending information about short-time voltage dips (e.g. during a
phone call) or decays.
6 Service options and parameters
In the keypad the options are available in SM
SETTINGS
Disable service mode [Block SM] – with this option enabled, entering the service mode
ssible (entering the service mode "from pins"
Hi
5. r parameters
submenu.
"from pins" (by hardware means) will be impo
will only be possible if the control panel factory settings are restored).
Disable downloading [Block DWNL] – with t n enabled, shis optio tarting communication with
the D
LOAD
X program "from pins" will be impossible.
de service mode after [Hide SM after] – the time counted from the last operation
performed in the service menu, after expiry of which the service mode menu will be hidden
(see: p. 5). If value 0 is programmed, the automatic hiding of the service mode will be
disabled.
Service mode beep [SM sounds] – with this option enabled, the service mode will be
acoustically signaled in the keypad.
7 Othe
Ri r] – number of rings after which the control panel will
code length] – the minimum required number of digits in the
ory values.
ngs before answer [Rings to answe
go off hook.
User code min. length [Min.
user code. The parameter will be taken into account when creating and editing the codes
(but it has no effect on the codes already existing in the system).
efix lengthPr the required number of digits in the prefix. Entering a number different from 0
means that from now each code will have to be preceded by a prefix:
normal – for everyday use. By default, it consists of a suitable number of digits 0 (e.g. if
the prefix length has been set at 4, the default prefix will be: 0000);
DURESS – to be used, when the user is forced to enter the code. If used, a silent alarm
will be triggered. By default, it consists of a suitable number of digits 4 (e.g. if the prefix
length has been set at 3, the default prefix will be: 444).
e prefixes and their validity can be programmed by the administratoTh r (master), using the
C
HANGE PREFIX
function.
Each change of the prefix length restores the prefix fact