If no key is pressed on the phone for 15 seconds, the control panel will hang up.
4. Upon pressing in turn the 0 and # keys on the telephone keypad, the control panel will
hang up.
10.2 Telephone control
1. Get access to the phone call answering function (steps 1-2 in section ANSWERING PHONE
CALLS
).
2. Within up to 15 seconds, press in turn the 2 and # keys on the telephone keypad. 4 short
beeps and 1 long beep will confirm that you have got access to the telephone control
function.
3. Within up to 15 seconds, enter the 2-digit number of the remote switch (e.g. 01, 07 or 15).
The control panel will inform you about the switch status change by means of sounds:
3 short beeps – the switch has been turned off;
4 short and 1 long beeps – the switch has been turned on.
The operating mode of the REMOTE SWITCH type output depends on how the output has
been configured by the installer.
4. Upon pressing in turn the 0 and # keys on the telephone keypad, the control panel will
hang up. You can also press the 1 and # keys to return to the phone call answering
function.
10.3 Audio alarm verification
Remote audio alarm verification is possible when the INT-AV module is connected to
the control panel.
1. Get access to the phone call answering function (steps 1-2 in section ANSWERING PHONE
CALLS
).
2. Within up to 15 seconds, press in turn the 3 and # keys on the telephone keypad. 4 short
beeps and 1 long beep will confirm that you have got access to the function of audible
alarm verification. The DTMF commands you can use after starting the listen-in / talk
session are described in the INT-AV module manual.
11. Operating the alarm system by means of keyfob
In the case of a control panel to which the ACU-100, ACU-250, INT-RX or INT-RX-S module
is connected, you can control the system using the keyfob. The user can have up to 2
keyfobs:
bidirectional APT-100 keyfob – supported by the ABAX system (ACU-100 controller
(firmware version 2.00 or newer) or ACU-250 controller);
433 MHz keyfob – supported by the INT-RX or INT-RX-S module.
One keyfob enables execution of up to 6 functions. For each keyfob, functions to be executed
upon pressing a button / combination of buttons, and for the APT-100 bi-directional keyfobs
also information to be displayed on the keyfob LEDs, are individually assigned (see: section
ADDING KEYFOB p. 28).