Permanent service access – the option is available to the master user (administrator). If
enabled, the installer has permanent access to the alarm system, which, among other
things, enables the control panel to be programmed by using LCD keypad or DLOADX
program.
Enabling PERMANENT SERVICE ACCESS option will clear the installer access time
programmed with the SERVICE ACCESS function. On the other hand, programming the
installer access time will disable the PERMANENT SERVICE ACCESS option.
Service can edit – the option is available to the master user (administrator). If it is
enabled, the installer can add, edit and delete users in the administrator's object.
Service arm/disarm/clear/bypass – the option is available to the master user
(administrator). If it is enabled, the installer can arm/disarm the system, clear alarms
and bypass zones in the administrator object.
Permanent DLOADX access – the option is available to the master user (administrator). If
it is enabled, the control panel can be programmed by means of the DLOADX program,
irrespective of whether or not the installer has access to the alarm system.
DloadX IP – enables programming the address of the computer, on which the DLOADX
program is installed. The address must be set if the control panel is to initiate
communication with the DLOADX program through Ethernet, using the TCP/IP protocols
(see: description of the ETHM-1 – DLOADX function, available in the DOWNLOADING
submenu). It can be entered as a name or IP address.
GuardX IP – enables programming the address of the computer, on which the GUARDX
program is installed. The address must be set if the control panel is to initiate
communication with the GUARDX program through Ethernet, using the TCP/IP protocols
(see: description of the ETHM-1 – GUARDX function, available in the DOWNLOADING
submenu). It can be entered as a name or IP address.
Erase service message – allows the user to delete the service message.
Tests – the following functions are available in the submenu:
Partitions – allows to check the status of partitions accessible to the user and operated
from the keypad. The partition status is presented by means of a symbol. The numbers
placed on the glass allow you to identify the partition numbers. By factory default, the
partition status is shown using the following symbols (which can be changed by the
installer):
b - temporary partition blocking,
? - entry delay,
E - exit delay (less than 10 seconds),
e - exit delay (more than 10 seconds),
P - fire alarm,
A - alarm,
p - fire alarm memory,
a - alarm memory,
a - zone is armed,
- violated zones,
- zone is disarmed, zones OK.
Zones – allows to check the status of zones in the partitions accessible to the user and
operated from the keypad. The zone status is presented by means of a symbol. The
numbers placed on the glass allow you to identify the zone numbers. On starting the
function, the status of zones 1-32 is displayed. Use the and keys to display the
status of other zones (see also description of the
LEDs, p. 8). By factory default, the