5.10 Zone bypassing
You can bypass / unbypass zones in the disarmed partitions. Violating a bypassed zone will
not trigger any alarm. Bypassing the zones is useful in case of damage or failure of the
detector connected to the zone, which results in malfunctioning of the alarm system (e.g.
triggering false alarms).
Zone bypassing reduces the level of protection. Prior to arming, make sure that there
are no accidentally bypassed zones in the partition, which might allow an intruder to
get access to the protected area despite arming.
If a zone is bypassed, call in the installer (service technician) immediately to repair the
defect.
For security considerations, the installer may reduce the number of zones that the user
will be allowed to bypass.
5.10.1 Zone inhibiting
The zones can be inhibited by the users having the ZONES BYPASSING right. The inhibited
zone will be bypassed until the partition to which the zone belongs is disarmed, or until the
zone is unbypassed by the user.
1. Enter the code and confirm with the
key
.
2. Press in turn the 4 and 1 keys. The list of zones will be displayed. There is an additional
symbol in the upper right-hand corner of the display to inform you about the given zone
status:
– the zone is not bypassed;
– the zone is inhibited;
– the zone is isolated.
3. Using the and keys, find in the list the zone which is to be inhibited.
4. Press any digit key until the symbol appears in the upper right-hand corner of the
display.
5. Repeat the steps 3 and 4 for the next zones which are to be inhibited.
6. Press the
key
. A message will inform you that the zones are inhibited.
Having started the INHIBIT function (step 2), you can press the or key to switch
over the keypad to the graphic programming mode (see: section SELECTION FROM THE
MULTIPLE-CHOICE LIST p. 15).
5.10.2 Zone isolating
The zones can be isolated by the users having the ZONES BYPASSING and ZONE ISOLATION
rights. The isolated zone will remain bypassed until unbypassed by the user.
1. Enter the code and confirm with the
key
.
2. Press in turn the 4 and 2 keys. The list of zones will be displayed. There is an additional
symbol in the upper right-hand corner of the display to inform you about the given zone
status:
– the zone is not bypassed;
– the zone is inhibited;
– the zone is isolated.
3. Using the and keys, find in the list the zone which is to be isolated.
Page view 31