Satel INTEGRA Plus User Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
38 User Manual SATEL
guard round confirmation;
enabling temporary partition blocking.
Most of the abovementioned functions are available after enabling the LOCK [LOCK
FEATURE] option for the partition keypad. Whether the functions are available may also
depend on the other keypad options (e.g. if the lock operates in the ON IF PARTITION
ARMED [ON IF PART.ARMED] mode, most of the functions will be unavailable).
6.2.2 [Code]
Depending on the user type and authority level, keypad settings and the alarm system status,
entering the code and confirming with the key will result in:
initiating the partition arming procedure;
disarming the partition;
– clearing alarm;
changing over the status of 25. BI SWITCH type outputs;
turning on the 24. MONO SWITCH type outputs;
guard round confirmation;
enabling temporary partition blocking;
unblocking cash machine access.
6.2.3 Quick arming
The installer can permit arming without the user authorization.
1. Select the arming mode (press one of the keys: 0 – full arming; 1 – full arming +
bypasses; 2 – arming without interior; 3 – arming without interior and without entry delay).
2. Press the
key
. The arming procedure will begin.
6.2.4 Triggering the alarm from keypad
The installer can permit triggering alarms from the keypad. To trigger an alarm, do the
following:
fire alarm – press the (INT-S) / (INT-SK) / (INT-SCR) key for approx. 3
seconds;
medical (auxiliary) alarm – press the 0 key for approx. 3 seconds;
panic alarm – press the (INT-S) / (INT-SK) / (INT-SCR) key for approx. 3
seconds. The installer defines whether the triggered alarm will be loud (setting off the loud
alarm signaling) or silent (without loud signaling).
6.2.5 Silencing the alarm sound at the keypad
If the keypad is signaling alarm, pressing any digit key will silence the signaling for approx. 40
seconds.
6.2.6 Code changing
The installer can permit the change of own code by means of the partition keypad.
1. Press the 1 key for 3 seconds.
2. When the
and
LEDs start blinking alternately, enter the old code and confirm it
with the
key.
3. When the and LEDs start blinking alternately, enter the new code and confirm it
with the
key.
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Comments to this Manuals

No comments