34 User Manual SATEL
between starting the function to the actual end of the test (during this the FINISH TEST
function will be still available).
12. Depending on the type of tested detector:
magnetic contact – open and close the door or window protected by means of the
magnetic contact;
motion detectors – pass in front of the detector;
other detectors – follow the manufacturer's directions for the detector testing.
13. Look through the test results. To do so, enter again the ZONES TEST submenu (see: steps
1-5) and start the VIEW RESULTS function. You can scroll through the list of results, using
the and keys. Press the or key to switch over the display to the graphic mode,
in which information is provided by means of symbols:
- zone was not violated,
- zone was violated.
Pressing the or key in the graphic mode will display information on another set of
zones (see also description of the LEDs, p. 8).
The test results can be deleted by means of the C
LEAR RESULTS function (TESTS
ZONES TEST CLEAR RESULTS).
5.14 Outputs control
If permitted by the installer, the control function can be started without user
authorization, upon pressing in turn the 8 and keys.
1. Enter the code and confirm with the
key
.
2. Press the 8 key. Depending on how the control panel has been configured by the installer:
a group of outputs will be displayed – using the and keys, find the group which
includes an output, and then press the
key to display the list of outputs;
the list of controllable outputs will be displayed at once.
3. Using the and keys, find in the list the output whose status you want to change to
control the device connected to the output. The output status is presented by means of
symbols:
- output inactive (disabled),
- output active (enabled).
The output status can be presented according to the zone status. The displayed
symbols should then be interpreted as follows:
- zone not violated (the device controlled by output is inactive);
- zone violated (the device controlled by output is active).
The way of presenting the status of roller shutter outputs differs from how the status of
other outputs is presented (see: section CONTROLLING THE ROLLER SHUTTER OUTPUTS).
5.14.1 Controlling the MONO SWITCH type of output
When the output is inactive:
– pressing the key will activate the output for the time programmed by the installer;
– pressing the key will allow you to program the time for which the output will be
activated upon the next pressing of the
key.
When the output is active, pressing any digit key will turn the output off.