File in DLOADX – displays the date and time of writing the data to the control panel by
means of the DLOADX program and the name of file with control panel data.
Panel version – displays information on the control panel firmware version.
STM program version – displays information on the program version of the processor
used to operate the control panel zones and power supply unit.
IP/MAC ETHM-1 – displays the IP address and MAC number of the ETHM-1 module
connected to the control panel.
Modules versions – allows to check the firmware versions for devices connected to the
control panel communication buses.
Time synchronization – allows to manually start synchronization of the control panel
clock and the time server. It applies to the control panel to which the ETHM-1 module is
connected. The address of time synchronization server must be programmed in the
control panel.
The function is unavailable, if the time synchronization is running. Automatic time
synchronization takes place every day at 05:30.
Service access – available to the master user (administrator). Allows to program the time
period of installer access to the alarm system. The time is programmed in hours.
Programming the value 0 means the installer will have no access.
Open door – allows to unlock the door controlled by the alarm system (modules executing
the access control functions) or activate the 101. CARD READ EXPANDER type outputs.
Outputs control – allow to control the devices connected to the MONO SWITCH, BI SWITCH,
REMOTE SWITCH, SHUTTER UP and SHUTTER DOWN type outputs (see: section OUTPUTS
CONTROL
p. 34).
Service mode – available to the installer. Initiates the service mode.
Take SM over – available to the installer. If the service mode has been initiated from another
keypad, it can be "taken over", i.e. the service menu can be displayed on the keypad, on
which the TAKE SM OVER function has been started.
Downloading – the following functions are available in the submenu
Start DWNL-RS – available to the installer. Enables the control panel to be programmed
locally by means of the D
LOADX program.
Finish DWNL-RS – available to the installer. Ends the local programming of control panel.
Start DWNL-MOD. – enables remote programming through an external modem (analog,
GSM or ISDN) by means of the D
LOADX program.
Start DWNL-TEL – enables remote programming through the built-in 300 bps modem,
using the DLOADX program.
ETHM-1 – DloadX – enables remote programming through the Ethernet (TCP/IP) by
means of the DLOADX program. The ETHM-1 module with firmware version 1.03 (or
newer) must be connected to the control panel.
ETHM-1 – GuardX – enables remote operation and administration through the Ethernet
(TCP/IP) by means of the GUARDX program. The ETHM-1 module with firmware version
1.03 (or newer) must be connected to the control panel).
5.4 Arming
This section describes the operations that must be carried out by the user from the keypad in
order to initiate the arming procedure. The arming procedure is ended at the running out of
the exit delay time (if the procedure is ended successfully, the system becomes armed – see
also F
AILURE OF ARMING PROCEDURE p. 23). If the exit delay time is 0, the system becomes
armed instantly.