24 User Manual SATEL
5.6 Two-code arming / disarming
If the partition is to be armed / disarmed with 2 codes, the user entering the first code must:
1. Enter the code and confirm with the
key
.
2. Scroll through the menu using the key until the ARM (2 CODES) / DISARM (2CODES)
function is found.
3. Press the
key
. Proceed in the same way as for the full arming of selected partitions
(steps 3-7).
4. If the installer has not set the code validity at 30 seconds, specify the code validity and
confirm with the key.
Prior to expiration of the code validity, the user entering the second code must arm / disarm
the partition using the:
LCD keypad (see: section ARMING or DISARMING AND ALARM CLEARING);
partition keypad ([code] );
reader (read-in of proximity card or DALLAS iButton).
The installer can configure the alarm system so that the second code will have to be
entered on another LCD keypad, partition keypad, etc.
5.7 Triggering the alarm from keypad
The installer can permit triggering alarms from the keypad. To trigger an alarm, do the
following:
fire alarm – press the key for approx. 3 seconds;
medical (auxiliary) alarm – press the key for approx. 3 seconds;
panic alarm – press the key for approx. 3 seconds. The installer defines whether the loud
panic alarm (setting off the loud alarm signal) or the silent panic alarm (without the loud
signal) will be triggered.
5.8 Users
The users can be added, edited and removed by:
master user (administrator);
installer (if the SERV. CAN EDIT option is enabled by the administrator);
user (if granted the U
SERS EDITING right).
The following data can be defined for the user:
Code – a sequence of digits for authorization of the user when using keypads and code
locks. The control panel supports codes consisting of 4 to 8 characters, however the
installer can define the minimum length of the code.
Telephone code – a sequence of digits for authorization of the user when using the
functions of telephone call answering and telephone control (see: section C
ALL ANSWERING
AND TELEPHONE CONTROL
p. 42).
Partitions – partitions to which the user has access (i.e. he is authorized to arm or disarm
them, clear alarms etc.).
Type – see: section U
SER TYPES p. 26.
User schedule – parameter for the SCHEDULED type code (see: section USER TYPES p. 26).
Validity time – parameter for the RENEWABLE, TEMPORARY or SCHEMATIC type codes (see:
section USER TYPES p. 26).