5
LED Functions
ALARM (red color) – blinking LED indicates alarm in partition. The LED goes out
after alarm reset (when none of LEDs is blinking, the alarm cause will be shown
by the function "Viewing alarm log". The alarm may have been caused by
a zone not displayed in the partition, or the zone belonged also to another
partition, where alarm was cleared).
TROUBLE (yellow color) – blinking LED indicates there is a failure in the alarm
system. With the option „keypad trouble alarm on until cleared” (FS131) active,
it is blinking until the trouble log is viewed (key 7 function) and the function is
finished by pressing the [#] key.
112
or
116
- (red color) LEDs indicating the status of system zones::
ON zone violated,
blinking fast alarm memory (the zone triggered alarm, but is not
violated any more),
ON with a short extinguishment every 2 seconds detector tamper
(2EOL zone type),
flashing every 2 seconds tamper memory (detector was tampered -
2EOL zone type),
blinking slowly – zone bypassed (indicated only with the partition
disarmed).
ARMED I, II, III, IV (yellow color) – The blinking LED indicates that partition exit
delay countdown is in process. Additionally, when the GO TO function is used,
the rapidly blinking LED indicates the partition currently controlled by the
keypad.
Note: When the function „display service message after tamper alarm” (FS131) is
active, the
[ALARM] LED, on detection of a tamper, is blinking until the
message is cleared with a service code
.
Functions of the LEDs change on calling the service mode or entering the user function
mode.
Some states of the control panel are additionally indicated by combinations of LEDs
[ALARM], [ARMED], [TROUBLE]:
[ALARM], [ARMED], [TROUBLE] blinking - control panel signals entering the
user function
[ALARM], [ARMED], [TROUBLE] on - control panel performs function
"Viewing alarm log"
[TROUBLE] blinking, [ALARM] and [ARMED] on - control panel performs
function "Viewing trouble log"
Additional signaling, which is only provided in the CA-10 KLED-S keypad:
LED designated with the symbol is lit when the keypad audible alarm (buzzer)
is on.
all LEDs blinking simultaneously (with 0,5s/0,5s timing), along with audible
signaling, informs the user that connection between the keypad and the control
panel has been lost.
keypad illumination blinking with a high frequency - the keypad is receiving data
from the control panel.