Technical Reliability of the Alarm System
The alarm system is built of the devices whose reliability is vital in effectiveness of
offered protection. The elements of the alarm system are subject to various outside
influences, for example weather conditions (outside signaling devices), lightning
(overhead telephone lines, power lines, outside signaling devices), mechanical damage
(keypads, detectors). Only permanent control of the alarm system operation ensures
keeping high level of burglary and fire protection.
The control panel is equipped with a number of safeguards and auto diagnostic
functions testing the reliability of the system. The control panel signals trouble detection
by switching the
[TROUBLE] LED on the keypad on. The signal should be
immediately taken care of - if necessary, the installer should be consulted.
It is necessary to periodically test the reliability of the alarm system - check every single
detector's ability to signal zone violation by opening the protected windows, doors etc. It
is also necessary to check signaling devices and telephone voice messaging system.
The installer provides detailed instructions on how the system should be checked. It is
recommended that the installer carry out periodic maintenance of the alarm system by
the user order.
In his best interest, the user should plan beforehand appropriate procedures in case the
control panel signals any alarm conditions. It is important that he should be able to
verify the alarm, determine its source on the basis of keypad information, and take an
adequate action, e.g., to organize evacuation.
Alarm System Operating Costs
The main task of the control panel is signaling and efficient reporting of alarm situations
and, in the case of the monitoring function, keeping the monitoring station informed
about the protected facility status. Performance of these functions is to a large extent
based on the use of a telephone line, which entails generating certain costs. Generally,
the level of costs incurred by the alarm system owner depends on the amount of
information the control panel has to transfer to the monitoring station. A failure of the
telephone links, as well as incorrect programming of the control panel, may to a large
degree increase these costs. Such a situation is usually related to an excessive number
of connections made.
The installer can adjust functioning of the alarm system to the specific conditions and
kind of the protected site, however it is the user who should decide if his or her priority is
transferring information at any price, or, if some technical problems occur, the control
panel is allowed to skip some events, the reception of which has not been confirmed by
the monitoring station.
CA-10 Control Panel
The CA-10 control panel is a modern, microprocessor-based equipment designed for
burglary and assault signaling systems. The CA-10 panel controls the alarm system,
responds to information coming from the system detectors about an intrusion into the
protected facility, and provides signaling and notification about the event. The control
panel can be operated by means of LED or LCD type keypads.
Basic functions of CA-10:
signaling burglary, panic and fire alarms,
telephone messaging about the alarms with voice or pager messages,