Satel CA-10 User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
CA-10 SATEL
11
In the LED keypad, the [TROUBLE] and [ARMED] will go on, the [ALARM] LED
will start blinking, while information on the last alarm will be shown on the LEDs 1-12.
Pressing any key (except for the [
*
] key, which stops viewing the alarms log
immediately), you can reach information on the previous alarms, until the end of the
events log. In the LCD keypads, the keys make it possible to scroll through the
alarms log, and the keys to get some extra information on the alarm source.
The panel signals three types of alarms: zone alarms, tamper zone alarms and keypad
activated alarms. In the LED keypads they are indicated as follows:
zone alarms: one of the LEDs 1-12 / 1-16 is steadily on
(burglary alarms, panic
alarms, fire alarms etc. depending on how the functions of the zones were set up
by the installer)
tamper alarms of 2EOL type zones: one of the LEDs 1 to 12 / 1-16 is blinking
(this type of alarm signals an attempt to dismantle or damage detectors or alarm
system wiring),
keypad activated alarms: the LEDs 1 to 8 are steadily on and two LEDs - one in
the 1 to 5 range and one in the 9 to 12 range - are blinking.
The LEDs have the following meaning:
1 - fire alarm keypad activated
2 - auxiliary alarm keypad activated
3 - panic alarm keypad activated
4 - tamper keypad alarm
5 - three wrong access codes alarm
9 - alarm activated in partition 1
10 - alarm activated in partition 2
11 - alarm activated in partition 3
12 - alarm activated in partition 4
Viewing troubles log [6]
The function allows the panel user to reproduce information about the system trouble
conditions from the panel memory log.
After calling the function in the LCD keypad, the message "View troubles log

"
will be displayed. Pressing any of the arrow keys causes the date, time, and last trouble
type detected name to appear. On pressing key the list of previously detected
troubles is displayed, on pressing key the list of subsequent troubles.
After calling the function in the LED keypad, the
[ALARM] and [ARMED] LEDs will,
the
[TROUBLE] LED will start blinking, and one of the LEDs 1 to 12 will indicate the
kind of trouble. The LEDs have the following meaning:
1 - output 1 trouble,
2 - output 2 trouble,
3 - output 3 trouble,
4 - 230VAC loss
5 - battery trouble
6 - keypad power supply trouble
7 - time not set
8 - printer trouble
9 - telephone line loss
http://www.ealarm.com.my
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 22 23

Comments to this Manuals

No comments