Satel INTEGRA User Manual Page 71

  • Download
  • Add to my manuals
  • Print
  • Page
    / 75
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 70
INTEGRA SATEL
69
12. BRIEF DESCRIPTION OF OPERATING THE SYSTEM FROM KEYPAD
lit – all partitions operated by the keypad are
armed
blinking – some partitions are armed
- 1. group (numbers: 1-32) / 1. expander bus
- 2. group (numbers: 33-64) / 2. expander bus
- 3. group (numbers: 65-96)
- 4. group (numbers: 97-128)
(
– LED OFF; – LED ON)
blinking – system trouble – use the TROUBLES
user function to view the troubles
blinking – service mode entered
lit or blinking – alarm or alarm memory in
one or more operated partitions
[CODE][
*
] – enter the user menu
User menu shortcuts:
1 Change own code
2 Users / Masters
21 New user / New master
22 Edit user / Edit master
23 Remove user / Remove master
4 Zone bypasses
41 Inhibit
42 Isolate
5 Events
51 Selected events
52 All events
6 Set time
7 Troubles
8 Outputs control
9 Service mode
0 Downloading
01 Start DWNL-RS
02 Finish DWNL-RS
03 Start DWNL-MOD.
04 Start DWNL-TEL
05 Start DWNL-CSD [INTEGRA 128-WRL]
06 Start DWNL-GPRS [INTEGRA 128-WRL]
07 ETHM-1 – DloadX
08 ETHM-1 – GuardX
Press and hold down selected keys for 3 seconds to:
[1] – view state of zones
[4] – view state of partitions
[5] – view alarm log
[6] – view trouble log
[7] – view current troubles
[8] – enable / disable CHIME
[9] – toggle the display between standby mode and all
partition state presentation mode
– trigger auxiliary alarm
– trigger fire alarm
– trigger panic alarm
T or S – view messages about zone alarms
W or X – view messages about partition alarms
[CODE][#] – arming / disarming / alarm
clearing
Quick arming:
[0][#] - fully armed
[1][#] - fully armed + bypasses
[2][#] - armed without interior
[3][#] - armed without interior and without
entry delay
[9][#] - end of exit delay countdown
[8][#] – quick control of outputs