INTEGRA SATEL
37
Note: The special armed modes, as described earlier, are also defined for timers.
partition arming control by means of a special zone programmed (by the installer) as
arming control zone. In practice, it may be a mechanical switch; key switch, pushbutton,
radio switch. It is also possible to control such a zone by means of the REMOTE SWITCH
type output (see: ANSWERING PHONE CALL). Disarming by means of the zone can also clear
the alarm and telephone messaging;
Note: The zone will arm always, unless the option CHECK ARM POSSIBILITY is enabled. If this is
the case, all the conditions which make arming impossible (see page 34) will be taken
into consideration.
arming/disarming by the use of code and arrow keys (see: USE OF LCD KEYPAD) – this
mode facilitates access to the above mentioned "special ways of arming".
6.11 ALARMS
The system may signal alarms as the response to various situations that occurred in the
protected facility. The basic control panel alarms include:
Burglary alarm – activated when the zone is violated in the partition where arming is on.
Violation of the “delayed zone" starts countdown of the delay time, after expiry of which
an alarm is activated unless the partition is disarmed.
Fire alarm – activated by fire detectors, from keypad or otherwise (e.g., by pressing
pushbutton).
Tamper alarm – activated by violation of any tamper contacts in the alarm system (located in
detector and module casings), damage to cables, etc.
Panic alarm – activated from keypad or otherwise as defined by the installer (e.g., by
pressing pushbutton).
Auxiliary alarm – activated from keypad (for example, call for medical aid) or otherwise as
defined by the installer (e.g., remote controller or pushbutton).
Technical alarm – activated by various specialist detectors.
The way of signaling individual alarms may be different, as defined by the system installer. It
may be an alarm siren, information to the monitoring station, visual alarm, audible alarm
and/or keypad message, telephone message, activation of other external devices.
The alarm can be cleared by a user authorized to clear alarms in the given partition/object.
The alarm will be cleared after entering the code and confirming it with the [#] key. If the user
is authorized to disarm the partition, the alarm clearance will be accompanied by disarming.
The disarming will not be effected automatically, if the user may disarm more than one
partition. He must then chose the partitions to be disarmed. He can also cancel the disarming
by pressing the [
*
] key. In order to clear the alarm without disarming the partition, it is
possible to use the user function CLEAR ALARM.
Immediately after the alarm is cleared, viewing of the violated zones is possible. If the user
decides not to view them immediately, he can do it at a later date by means of the user
option VIEW CLEARED ALARMS. The function will be available in the user menu until the viewing
is done.
6.12 ALARM MESSAGING BY TELEPHONE
All the INTEGRA series control panels can inform about events in the system by means of
voice messages (connection of voice synthesizer is required), as well as PAGER type text
messages. The INTEGRA 128-WRL control panel can additionally notify by means of SMS
type messages. The SATEL made GSM modules offer the feature of converting the PAGER