SATEL ETHM-1 15
key for data encryption (identical to that programmed in the module for communication
with the G
UARDX program);
address of the ETHM-1 module, if communication is to be initiated from the GUARDX
program.
Fig. 10. GUARDX program: settings for communication via Ethernet (TCP/IP) network.
6.1.3 Initiating connection from the GUARDX program
1. In the startup window, "Connection" field, select "GuardX -> ETHM" (see Fig. 9), and then
click on the "Start" button.
2. After establishing connection, a window will open, where you must enter the code of
control panel administrator / user.
6.1.4 Initiating connection from the keypad (by the control panel)
1. In the startup window, "Connection" field, select "GuardX <- ETHM", and then click on the
"Start" button.
2. In the keypad, start the ETHM-1 GUARDX function ([code] DOWNLOADING ETHM-1
GUARDX). The function is available to the service, administrator and user having the
DOWNLOADING STARTING right.
3. After establishing connection, a window will open, where you must enter the access code
of control panel administrator / user.
6.2 Web browser
6.2.1 Configuring the ETHM-1 module
In the module ETHM-1:
enable the WWW option;
program the key for data encryption during communication with the JAVA application in
web browser (GUARDX/JAVA KEY);